High Energy Physics Products

Delay Line Detectors

Delay line detectors give your products the ability to precisely measure timings, matching patterns, and signal synchronization by delaying and phase-shifting incoming signals. At PMT, we offer a diverse selection of delay line detectors, from large imaging detectors to specialized DLDs with photoemission electron microscopes and interchangeable mechanics. Our delay line detectors are the perfect product solution for many applications, including electron spectroscopy, X-rays, and UV diffractions. PMT delay line detectors and support solutions are here to help you design and quickly produce a product your clients will love, no matter your clientele, from medical to military. Give us a call, and our team will direct you to the best product solution for you.

Delay Line Detectors

Detection of Electrons, Ions & Photons With SUB-NS Time Resolution.

Delay Line Detectors

MULTI-HIT 4-QUADRANT DLD SYSTEMS

DLD-3030-4Q

4-quadrant delay line detector for parallel multi hit detection of electrons, ions, UV and X-ray with burst count rates of above 100 MCPS.

Typical applications: Particle detection with extremely high burst count rates in pulsed experiments, e.g. mass spectrometry (TOF-SIMS, RIMS, MALDI).

Delay Line Detectors

SMALL IMAGING DETECTORS WITH TIME RESOLUTION (3D DETECTOR SYSTEMS)

  • DLD-3030, DLD-3636, DLD-4040 (customized up to DLD-4545)
  • Imaging DLD with delay line anode area up to 45 x 45 mm².
  • High count rates, small deadtimes, compact design.

Typical applications: Electron Spectroscopy, Time Resolved Photoemission Electron Microscopy (TOF-PEEM), Mass Spectrometry (TOF-SIMS, RIMS, MALDI), X-ray microscopy, X-ray holography, X-ray spectroscopy.

Delay Line Detectors

DLDS FOR USE WITH A PHOTOEMISSION ELECTRON MICROSCOPE (PEEM)

DLD-3636

Standard delay line detector for photoemission electron microscopes. Delay line anode area: 36×36 mm&sub2; – mounting flange: DN63CF.

Delay Line Detectors

LARGE IMAGING DETECTORS WITH TIME RESOLUTION (3D DETECTOR SYSTEMS)

DLD-6565, DLD-8080, DLD-120120

Imaging DLD with delay line anode area up to 120 x 120 mm². High count rates, large active detector areas, high lateral resolution, large pixel numbers (up to 10,000 x 10,000).

Typical applications: Medium Energy Ion Scattering (MEIS), Atom Probe Microscopy (APM), Field Ion Microscopy (FIM), X-ray microscopy, X-ray holography, X-ray spectroscopy.

Delay Line Detectors

INTERCHANGEABLE DLD-4040-IC

DLD mounted on a linear drive for in-situ exchange between DLD and the imaging unit of the PEEM. Delay line anode area: 40×40 mm&sub2;- mounting flange: DN63CF or DN100CF.

Delay Line Detectors

LINE DETECTORS WITH TIME RESOLUTION (1D-2D DETECTOR SYSTEMS)

DLD-43, DLD-64

Line detectors for 1D (multi channel) / 2D (multi channel + time) detection in electron spectroscopy as well as for X-ray, UV, and charged particle applications.

Typical applications: multi channel detection in electron energy analyzers, X-ray and UV-diffraction.

Delay Line Detectors

TIME RESOLVING X-RAY, EUV DETECTORS

DLD-3636-XR

DLD with polyimid window for the laterally and timeresolved detection of X-rays. Delay line anode area: 36×36 mm&sub2;.